PENGARUH DENSITAS ARUS LISTRIK TINGGI DENGAN KADAR GRAFIT TERHADAP EFEKTIFITAS CATHODIC PROTECTION BETON MUTU TINGGI

Nathaniel Evan Wijaya(1*), Calvin - Limantoro(2), Daniel - Tjandra(3), Gunawan Budi Wijaya(4),


(1) Mahasiswa Program Studi Teknik Sipil Universitas Kristen Petra
(2) Mahasiswa Program Studi Teknik Sipil Universitas Kristen Petra
(3) Dosen Program Studi Teknik Sipil Universitas Kristen Petra
(4) Dosen Program Studi Teknik Sipil Universitas Kristen Petra
(*) Corresponding Author

Abstract


Korosi merupakan masalah yang sering terjadi pada tulangan baja pada struktur beton bertulang. Bila dibiarkan, beton akan mengalami retak (crack) dan menyebabkan kegagalan struktur. Untuk mengatasi masalah tersebut, diperlukan metode perlindungan Impressed Current Cathodic Protection (ICCP) dengan Carbon Fiber Reinforced Polymer (CFRP) laminate sebagai anoda sekaligus menambah perkuatan struktur (dual system). Korosi awal diberikan, setelah itu CFRP laminate ditempelkan pada spesimen beton bertulang menggunakan epoxy dengan kadar grafit 10% dan 12,5%. ICCP dengan 2 macam densitas arus (70 mA/m2 dan 106 mA/m2) diberikan pada spesimen dengan mutu beton fc’ 50 MPa. Dalam pelaksanaan, dilakukan half cell potential test untuk monitoring korosi pada spesimen dan pengamatan visual pada tulangan baja dan CFRP laminate diakhir pelaksanaan. Terdapat pengaruh yang signifikan terhadap peluang terjadinya korosi pada variasi mutu beton. Beda potensial pada beton mutu tinggi sangat kecil karena beton mutu tinggi memili resistivity yang tinggi. Perubahan beda potensial yang paling signifikan ditunjukan pada kadar grafit 12,5% dengan densitas arus 70 mA/m2, yaitu sebesar 191,12 mV pada fc’ 50 MPa. Namun meskipun hasil yang didapat memiliki nilai yang positif, perbedaan beda potensial pada grafit 12,5% dan 10% yang menggunakan densitas arus 70 mA/m2 tidak terlalu signifikan bila dibandingkan dengan densitas arus 10 mA/m2.

Keywords


korosi, impressed current cathodic protection, mutu beton, densitas arus, kadar grafit, korosi, carbon fiber reinforced polymer laminate

Full Text:

PDF

References


Ahmad, S. (2009). “Techniques for Inducing Accelerated Corrosion of Steel in Concrete.” Arabian Journal for Science and Engineering. Vol. 34, No. 2, 95–104.

ASTM Committee G01. (2009). Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete. West Conshohocken, PA: America Society for Testing and Materials

Badan Standarisasi Nasional. (2013). Persyaratan Beton Struktural untuk Bangunan Gedung (SNI 2847:2013). Jakarta

Bahekar, P. V., & Gadve, S. S. (2017). “Impressed Current Cathodic Protection of Rebar in Concrete Using Carbon FRP Laminate.” Construction and Building Materials. Vol. 156, 242–251. https://doi.org/10.1016/j.conbuildmat.2017.08.145

British Standards Institution. (2012). BSI Standards Publication Cathodic Protection of Steel in Concrete (ISO 12696 : 2012). United Kingdom: BSI Standards Limited 2012

Broomfield, J. P. (2006). Corrosion of Steel in Concrete: Understanding, Investigation and Repair, Second Edition. https://doi.org/10.4324/9780203414606

Elsener, B. (2003). “Half-Cell Potential Measurements – Potential Mapping on Reinforced Concrete Structures.” Materials and Structures / Materiaux et Constructions, 36(7), 461 – 471. doi: 10.707/BF02481526

Gadve, S., Mukherjee, A., & Malhotra, S. N. (2011). “Active Protection of Fiber-Reinforced Polymer-Wrapped Reinforced Concrete Structures Against Corrosion.” Corrosion, 67(2), 025002-1 – 025002-11. doi: 10.5006/1.3549564

Kevin, Linggadiharja, G. C., Wijaya, G. B. & Tjandra, D. (2019). “Pengaruh Mutu Beton terhadap Efektivitas Impressed Current Cathodic Protection dengan Carbon Fiber Reinforced Polymer sebagai Anoda.”

Kim, M. J., & Ann, K. Y. (2018). “Corrosion Risk of Reinforced Concrete Structure Arising from Internal and External Chloride.” Advances in Material Science and Engineering, 2018(2), 1–7. doi: 10.1155/2018/7539349

Lu, Y. yan, Hu, J. yue, Li, S., & Tang, W. shui. (2018). “Active and Passive Protection of Steel Reinforcement in Concrete Column Using Carbon Fibre Reinforced Polymer Against Corrosion.” Electrochimica Acta, 278, 124–136. https://doi.org/10.1016/j.electacta.2018.05.037

Nguyen, C. V., Mangat, P. S., Lambert, P., O’Flaherty, F. J., & Jones, G. (2014). “Dual Function Carbon Fibre Reinforced Anode System for Concrete Structures.” Materials and Structures. Vol. 48, No. 7, 2157 – 2167. https://doi.org/10.1617/s11527-014-0300-0

Wijaya, G. B., Lays, D. P., Tanto, H. H. & Tjandra, D. (2019). “Study on Graphite Powder as Conductive Pigments for Impressed Current Cathodic Protection System using Carbon Fiber Reinforced Polymer Anode.” Civil Engineering Dimension, 21(2), 84-88.

Wilson, K., Jawed, M., & Ngala, V. (2013). “The Selection and Use of Cathodic Protection Systems for the Repair of Reinforced Concrete Structures.” Construction and Building Materials. Vol. 39, 19-25. http://dx.doi.org/10.1016/j.conbuildmat.2012.05.037


Refbacks

  • There are currently no refbacks.


Jurnal telah terindeks oleh :