Abstract


PT. X wants to reduce their flow out, because their flow out rate is bigger than the target. Flow out is a condition where the reject product slip away to customer or the next process. The purpose of this research is identifying flow out’s root cause and giving some improvement suggestions. Fishbone Diagram is used to identify the root cause. FMEA and Pareto chart are used to make improvement priority. The improvements are prioritized in man and machine aspect. The root cause from machine aspect are tooling utilizing and machine performance, meanwhile the root cause from man aspect are technician control and the selector’s inspection. The solutions given are doing the tooling stock opname and giving the workers continual training.

Keywords


Quality control, Fishbone, FMEA.

Full Text:

PDF

References


McDermott, E. R., Mikulak, J. R., & Michael, B. R. (1996). The Basic of FMEA. New York: Resource Engineering, Inc.

Gygi, C., DeCarlo, N., & Williams, B. (2005). Six Sigma for Dummies. Indianapolis: Wiley Publishing.

Sayer, N. J., & Williams, B. (2007). Lean For Dummies. Canada: Wiley Publishing, Inc.


Refbacks